MEASURING INSTRUMENTS CATALOG No.E2016
565/682

K-12KMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.Non-contact and contact measurement with one machineQV touch probe unit enables both vision measurement and touch probe measurement.3D workpiece measurementMeasures three-dimensional workpieces such as molded products resin molded products, machined products, and more. Module change rack availableEasily change between vision and touch probe measurement with a module change rack.Specifications with touch probe options mountedMaster ballCalibration blockModule change rack, MCR20PH6TP20 QV TPSERIES 364 — CNC Vision Measuring System equipped with a Touch Trigger ProbeSafety precautions regarding laser autofocus system (factory-installed option)This product uses a low-power visible laser (690nm) for measurement. The laser is a CLASS 1 EN/IEC60825-1 (2007) device. A warning and explanation label, as shown above, is attached to the product as appropriate.Safety precautions regarding QV HYBRID TYPE1.This product uses a low-power visible laser (780nm) for measurement. The laser is a CLASS 1 EN/IEC60825-1 (2007) device. A warning and explanation label, as shown above, is attached to the product as is appropriate.QV TP Apex302Hyper QV TP302QV TP Apex404Hyper QVz TP404QV TP Apex606Hyper QV TP606 Measuring range*1 (X×Y×Z)Vision300×200×200mm400×400×250mm600×650×250mmCommon to Touch Trigger Probe234×200×200mm334×400×250mm534×650×250mmMeasuring accuracy*2 (Touch probe)E1X,E1Y,E1Z QV TP Apex: (1.8+3L/1000)μmHyper QV TP: (1.7+3L/1000)μmQV TP ACCEL 808QV TP ACCEL 1010QV TP ACCEL 1212QV TP ACCEL 1517Measuring range*1 (X×Y×Z)Vision800×800×150mm1000×1000×150mm1250×1250×100mm1500×1750×100mmCommon to Touch Trigger Probe734×800×150mm934×1000×150mm1184×1250×100mm1434×1750×100mmMeasuring accuracy*2 (Touch probe)E1X,E1Y,E1Z(1.8+3L/1000)μm(3+4L/1000)μm(6+7L/1000)μm*1: When a module change rack, a master ball, and a calibration ring are mounted, the measurement ranges are smaller than those in the table. Other specications are the same as those of QV Apex, Hyper QV, and QV ACCEL.Please contact our sales ofce for more details.*2: Inspected by Mitutoyo standard. L = length between two arbitrary points (mm)Refer to the QUICK VISION (Catalog No.E14007) for more details.

元のページ 

page 565

※このページを正しく表示するにはFlashPlayer10.2以上が必要です