MEASURING INSTRUMENTS CATALOG No.E2016
564/682

K-11KVision Measuring SystemsVision measuring systems for multipurpose useMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.Hyper QV WLISERIES 363 — Non-contact 3D measuring systemApplication exampleSi mold line and 10/10µm pitch spacing•QV WLI alone can measure coordinates and dimensions and assess micro-3D forms without contact.•This machine is a high accuracy, dual-head vision measuring system equipped with a white light interferometer.•The white light interferometer uses high aspect ratio to accurately measure shapes.• The standard vision measuring function can continuously perform coordinate, dimension and 3D shape measuring without interruption.• The large work stage accurately handles large-sized work pieces such as a PCB.2D measurement using vision head3D form analysis (arbitrary angle display)Section measurementSPECIFICATIONSHyper QV WLI 302Hyper QV WLI 404Hyper QV WLI 606Measuring range (X×Y×Z)Vision measuring area300×200×190 mm 400×400×240mm 600×650×220mmWLI measuring area*1215×200×190 mm 315×400×240mm 515×650×220mmWLI optical head unitView eld (H×V)5X lens: approx. 0.64×0.48mm / 10X lens: approx. 0.32×0.24mm / 25X lens: approx. 0.13×0.10mmRepeatability2σ ≤ 0.08μmZ-axis scanning range*2170μmVision optical head unitMagnication change systemPPT1X-2X-6XImage detection methodB&W CCD cameraIlluminationCo-axial LightWhite LEDTransmitted LightWhite LEDProgrammable ring Light White LEDMeasuring accuracyE1X, E1Y(0.8+2L/1000)μmE1Z(1.5+2L/1000)μmE2XY(1.4+3L/1000)μmMain unitResolution0.01μmMax. stage loading15kg25kg35kgGuidance systemDirect acting type hard bearingDimensions (W×D×H)859×950×1606 mm1027×1407×1781 mm1309×1985×1792 mmMass (vibration isolator stand included)Approx. 490kgApprox. 1160kgApprox. 2275kg*1: Movable range of WLI optical head. *2: In case of standard mode. Applicable to max. 200μm by modifying scan pitch.*3: Determined by Mitutoyo’s inspection method. L is measured length (mm). The optical condition for accuracy assurance is to be (QV-HR2.5X or QV-SL2.5X) + Middle magnication of the tube lens.*4: An excessively biased or concentrated load is excluded.* Append "S" to the end of code number to order a QV machine compatible with ISO10360-7:2011 Accuracy Assurance.* Hyper QV WLI is not compatible with the Easy Editor function of QVPAK.Hyper QV WLI 606Refer to the QUICK VISION (Catalog No.E14007) for more details.

元のページ 

page 564

※このページを正しく表示するにはFlashPlayer10.2以上が必要です