MEASURING INSTRUMENTS CATALOG No.E2016
527/682

J-6JMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.PH-3515F, PH-A14SERIES 172 — Profile Projector•Bench-top model uses a horizontal optical system.•Maximum loading of workstage (45kg) allows the measurement of heavy workpieces.•Wide measuring range 254mm (X) × 152mm (Y) allows measurement of large workpieces. (PH-3515F)•Digital display of protractor screen angle enables easy angular measurement. (PH-3515F)•Combination use with the optional 2-D data processor QM-Data200 facilitates a variety of dimensional measurement methods•Provides transmitted illumination for inspecting workpiece contour, and oblique incident illumination for the observation of workpiece surfaces.PH-3515FPH-A14SPECIFICATIONSModel No.PH-3515FPH-A14Order No. 172-868*1 172-810*2Projected imageErect-reversedInvert-reversedProtractor screenEffective diameterø353mm (13.9”)ø356mm (14”)Screen materialFine-ground glassScreen rotation±360°(±370°for display)Angle displayDigital counter (LED) (ABS/INC mode switching), Zero SetVernierResolution1’ or 0.01° (switchable)2’ (graduation)MechanismFine feed and clampCross-hairs90°(solid lines)Projection lensMagnication10X (standard accessory), 5X(PH-3515F only), 20X, 50X, 100XLens mountScrew mountMagnication accuracyTransmitted illuminationLess than ±0.1% of nominal magnicationSurface illuminationLess than ±0.15% of nominal magnicationIllumination*3Transmitted illuminationHalogen bulb (24V, 150W, 500hours) (No.515530)Telecentric system, Heat-absorbing lter, Built-in cooling fan2-step (High/Low) brightness switch, Combination use with a color lter availableSurface illuminationParabolic halogen bulb (24V, 200W, 500hours) (No.12BAA637)Beam concentration and adjustment available, Heat-absorbing lter, Built-in cooling fanResolution for X/Y counter *4—Measuring unitDigital scaleMeasuring range (X×Y)254×152mm200×100mm*1: To denote your AC power cable add the following sufxes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No sufx are required for PSE.*2: To denote your AC power cable add the following sufxes to the order No.: -10A for UL/CSA, -20D for CEE, -20DC for CCC, -20E for BS, -20K for KC.*3: For the PH-A14, a light source (24V 150W), which is common to the Transmitted illumination and Surface illumination, is used.It is not possible to regulate brightness.*4: XY counter is not built in the main unit of PH-3515F and PH-A14. If the counter display is required, it is recommended to purchase QM-Data200 or a counter (KA-212) separately.Note1: Depending on the angle of illumination, measurement results may be smaller than actual values.Refer to the Measuring Projector (Catalog No.E14005) for more details.

元のページ 

page 527

※このページを正しく表示するにはFlashPlayer10.2以上が必要です