MEASURING INSTRUMENTS CATALOG No.E2016
462/682

G-31GLaser Scan MicrometerTo realize non-contact, high-speed and high-precision measurement Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.Head■Plain Stem and Stem with Clamp NutThe stem used to mount a linear gage head is classied as a "plain type" or "clamp nut type" as illustrated below. The clamp nut stem allows fast and secure clamping of the linear gage head. The plain stem has the advantage of wider application and slight positional adjustment in the axial direction on nal installation, although it does requires a split-xture clamping arrangement or adhesive xing. However, take care so as not to exert excessive force on the stem.■Measuring ForceThis is the force exerted on a workpiece during measurement by the contact point of a linear gage head, at its stroke end, expressed in newtons.Stem locknut typePlain stem■Comparative MeasurementA measurement method where a workpiece dimension is found by measuring the difference in size between the workpiece and a master gage representing the nominal workpiece dimension. ナット付ステムストレートステム■Precautions in Mounting a Gage Head●Insert the stem of the gage into the mounting clamp of a measuring unit or a stand and tighten the clamp screw.●Notice that excessively tightening the stem can cause problems with spindle operation.●Never use a mounting method in which the stem is clamped by direct contact with a screw.●Never mount a linear gage by any part other than the stem.●Mount the gage head so that it is in line with the intended direction of measurement. Mounting the head at an angle to this direction will cause an error in measurement.●Exercise care so as not to exert a force on the gage through the cable.●Machine the clamping hole so that its axis is parallel with the measuring direction. Mounting the gage at an angle will cause a measuring error.●When xing the Laser Hologage, do not clamp the stem too tightly. Over-tightening the stem may impair the sliding ability of the spindle.●If measurement is performed while moving the Laser Hologage, mount it so that the cable will not be strained and no undue force will be exerted on the gage head.StemStemClamp screwClamp screwClampClamp■Precautions in Mounting a Laser HologageTo x the Laser Hologage, insert the stem into the dedicated stand or xture.Display Unit■PresettingAny numeric value can be set on the display unit for starting the count from this value.■Direction changeoverThe measuring direction of the gage spindle can be set to either plus (+) or minus (-) of count.■MAX, MIN, TIR SettingsThe display unit can hold the maximum (MAX) and minimum (MIN) values, and the run out value (TIR) during measurement.■Tolerance SettingTolerance limits can be set in various display units for automatically indicating if a measurement falls within those limits.■Open Collector OutputAn external load, such as a relay or a logic circuit, can be driven from the collector output of an internal transistor which is itself controlled by a Tolerance Judgement result, etc.■Relay outputContact signal that outputs the open/closed status.■Digimatic CodeA communication protocol for connecting the output of measuring tools with various Mitutoyo data processing units. This allows output connection to a Digimatic Mini Processor DP-1VR for performing various statistical calculations and creating histograms, etc.■BCD OutputA system for outputting data in binary-coded decimal notation.■RS-232C OutputA serial communication interface in which data can be transmitted bi-directionally under the EIA Standards.For the transmission procedure, refer to the specications of each measuring instrument.振れ値=最大値-最小値MAXMIN0.0000.0000.000+/-基準面1.234123.456G■Zero-settingA display value can be set to 0 (zero) at any position of the spindle.IP54 protection codeTypeLevelDescriptionProtects the human body and protects against foreign objects5: Dust protectedProtection against harmful dustProtects against exposure to water 4: Splash-proof typeWater splashing against the enclosure from any direction shall have no harmful effect.IP66 protection codeTypeLevelDescriptionProtection against contact with the human body and foreign objects6: Dust tightProtection from dust ingressComplete protection against contactProtects against exposure to water 6: Water-resistant typeWater jets directed against the enclosure from any direction shall have no harmful effects.■Ingress Protection CodeLinear GagesQuick Guide to Precision Measuring InstrumentsDatum planeRunout value (TIR) = MAX - MINRecommended hole diameter on the xing side: 15mm +0.034/-0.014G-31

元のページ 

page 462

※このページを正しく表示するにはFlashPlayer10.2以上が必要です