MEASURING INSTRUMENTS CATALOG No.E2016
41/682

A-14AMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.Specications• Order No.: 264-002• Model: MUX-10F• Data input port: 4 channels for Digimatic gages • Output: (RS-232C)• Data output Via RS-232C interface: Data transmission method: Half-duplex Data transmission code: ASCII/JIS Data length: 8 bits Parity check: None Stop bit: 1 Data transmission speed: 300/600/1200/2400/9600/19200bps• Connector specication: • Data format (1) When data output (2) Example of format (3) Error code output• Power supply: AC adapter (9V, 500mA) External dimensions: 91.4 (W) x 92.5 (D) x 50.4 (H) mmNote: Communication software is not attached.D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13Data format code No.: 0Display (CH1)Output data 01A - 0000.018CR-0.018Channel No.: 1-4Measurement item: ALSD (Floating decimal point)Model: + or –CRD1 D2 D3 D4 Error format: 9Channel No.: 1 - 41: No data input2: Loaded data with format other than speciedError code No.CRDisplay (CH2)Output data02A + 000.1234CR0.1234The smallest input channel number data is output rst in the output stream, with the others following in ascending order.Digimatic/RS-232C Interface UnitMultiplexer MUX-10F• Multiplexer MUX 10F is a measurement data transfer device that converts incomingDigimatic output measurement data to RS-232C and outputs it to an external device such as a PC. Up to four measuring instruments with Digimatic output can be connected.264-002MUX-10FUsage ExampleData input using the data button on the Digimatic gage• If the Digimatic gage has a data button, data is sent to the MUX-10 from the gage, converted to RS-232C and sent out.Data input using the load switch• If the Digimatic gage does not have a data button, or when simultaneous measurements are performed, the MUX-10 load switch is used to poll data from the measuring gage(s) selected by the tool selection switch(es), converted to RS-232C, and sent out.• If multiple measuring gages are selected by the tool selection switch, data is input in the order of channels 1 through 4.• Optional foot switch (937179T) is available for quick data entry.Data input using the external commands• Data from a specied measuring gage connected to MUX-10F can be polled (ch 1- 4) by inputting a command from the PC.Operate the load switch on the front of MUX-10F.Tool Select SwitchDigimatic outputPCFoot switchMUX-10FDigimatic outputPCMeasurement dataCommandMUX-10FRS-232C(ASCII cod)Press the data button on the measuring gage.Digimatic outputPCMUX-10FPin No.SignalFunctionin/out1CDout2RDReceived dataout3TDCommunication datain45GNDGround6DRout78CSout9* For connection with a PC, use a commercially available RS-232C straight cable. Commands (ASCII)Transfer channels1 (ASCII code31) CR12 (ASCII code32) CR23 (ASCII code33) CR34 (ASCII code34) CR4*A (ASCII code41) CR1, 2, 3, 4*B (ASCII code42) CR1, 2, 4*C (ASCII code43) CR1, 3, 4*D (ASCII code44) CR2, 3, 4E (ASCII code45) CR1, 2, 3F (ASCII code46) CR1, 2G (ASCII code47) CR1, 3H (ASCII code48) CR1, 4I (ASCII code49) CR2, 3J (ASCII code50) CR2, 4K (ASCII code51) CR3, 4* Command will operate the same as previous MUX-10 when 4-channel mode is turned off.

元のページ 

page 41

※このページを正しく表示するにはFlashPlayer10.2以上が必要です