MEASURING INSTRUMENTS CATALOG No.E2016
276/682

D-57DMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.• Best-in-class accuracy ±(2.4+2.1L/600)μm• Newly developed high accuracy and high resolution ABSOLUTE linear encoder for position detection. Once origin is set, origin setting is not required each time you turn the power ON (except in the case of a large environmental temperature change).• GO/±NG judgment is performed by setting upper and lower tolerances. If a judgment result is out of tolerance, the display backlighting changes from green to red, so tolerance judgment can be made at a glance.• Frequent-use measurement such as inside/outside diameter and pitch calculation can be implemented by icon-based commands that also support easy one-key operation. • Possible to measure inside/outside diameters via a unique method (detect the circle apex and process by tracing measurement*).* Tracing measurement stroke is approx. 1mm upwards and downwards from the measurement start point.• Built-in air-suspension feature mechanism using an internal pump enables smooth movement over a surface plate.(Lower-cost version without air suspension also available.)• With SPC and RS-232C output.• Continuous battery life of 300 hours*5 using four alkaline batteries.(Also works with four NiMH AA/HR6 rechargeable batteries.)QM-HeightSERIES 518 — High Precision ABSOLUTE Digital Height Gage518-236Height GageA standard measuring tool of industryAn inspection certicate is supplied as standard. Refer to page X for details.(Refer to page X for details.)Standard accessories05HZA148 5-stepped probe 12AAA715 Ball-diameter corrected blockAuxiliary gripOptional accessories12AAC072: Depth probe12AAA792: Dial indicator (ø8mm stem) holder12AAA793: Probe extension holder (85mm/3.3”)12AAF667: ø2mm ruby ball probe (coaxial type)957261: ø2mm ball probe (coaxial type)957262: ø3mm ball probe (coaxial type)957263: ø4mm ball probe (coaxial type)957264: ø14mm disk probe957265: ø20mm disk probe12AAA788: ø4mm ball offset probe12AAA789: ø6mm ball offset probe226116: Test indicator (ø6mm stem) adapterSample workpiece 12AAA879Scriber 05HZA173Digimatic connecting cable 936937 (1m) 965014 (2m)AC Adapter 06AEG180JA/D/E/K/DC05HZA143: 9x9 adapter (clamp 901385 is required)05GZA033: Clamp (for 9x9 adapter)05HZA144: 6.35x12.7 adapter (clamp assy. 901385 is required)901385: Clamp assy. (for 6.35x12.7 adapter)02AZE990: U-WAVE mounting plateMetricCode No.518-230518-232518-234518-236Measuring range (stroke)0 -465mm(350mm)0 -715mm(600mm)0 -465mm(350mm)0 -715mm(600mm)Resolution (selectable)0.001mm/0.005mm0.001mm/0.005mm0.001mm/0.005mm0.001mm/0.005mmAccuracy at 20˚CMeasurement*1± (2.4+2.1L/600) µmRepeatability*121.8µmPerpendicularity*2 (20˚C)7µm12µm7µm12µmGuiding methodRoller bearingDrive methodManual (wheel)Measurement principleElectromagnetic induction absolute encoderMeasuring force1.5±0.5NData output portsDigimatic / USB*3Air-suspension featureNot includedNot includedIncluded (for positioning only)*4Included (for positioning only)*4Power supplyAlkaline AA/LR6 batteries × 4 (standard accessories) / AC adapter (optional accessory) / Supports NiMH (HR6) rechargeable batteries × 4Battery life guidelines*5Approx. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 100 hours (continuous use)LED: Full-time illumination Approx. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 100 hours (continuous use)LED: Full-time illumination Approx. 300 hours (continuous use)LED: Other than full-timeilluminationApprox. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 3.3 days when the air-suspension feature is used for 0.5 hours/day.Approx. 3.3 days when the air-suspension feature is used for 0.5 hours/day.Mass25kg29kg25kg29kgSize (mm)Stroke 350mm type: 280(W)x273(D)x784(H)mmStroke 600mm type: 280(W)x273(D)x1016(H)mmOperating temperature range (recommended)0 − 40˚C (10 − 30˚C)Operating temperature range20 - 80%RH (Must be free from condensation)Storage temperature range-10˚C − 50˚CStorage humidity range5 - 90% RH (Must be free from condensation)Inch/MetricCode No.518-231518-233518-235518-237Measuring range0-465mm(0 - 350mm/0-14”)0-715mm(0 - 600mm/0-24”)0-465mm(0 - 350mm/0-14”)0-715mm(0 - 600mm/0-24”)Resolution (selectable)0.001mm/0.005mm/.00005”/.0001”/.0002”0.001mm/0.005mm/.00005”/.0001”/.0002”0.001mm/0.005mm/.00005”/.0001”/.0002”0.001mm/0.005mm/.00005”/.0001”/.0002”Accuracy at 20˚CMeasurement*1± (2.4+2.1L/600) µmRepeatability*121.8µmPerpendicularity*2 (20˚C)7µm12µm7µm12µmGuiding methodRoller bearingDrive methodManual (wheel)Measurement principleElectromagnetic induction absolute encoderMeasuring force1.5±0.5NData output portsDigimatic / USB*3Air-suspension featureNot includedNot includedIncluded (for positioning only)*4Included (for positioning only)*4Power supplyAlkaline AA/LR6 batteries × 4 (standard accessories) / AC adapter (optional accessory) / Supports NiMH (HR6) rechargeable batteries × 4Battery life guidelines*5Approx. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 100 hours (continuous use)LED: Full-time illumination Approx. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 100 hours (continuous use)LED: Full-time illumination Approx. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 300 hours (continuous use)LED: Other than full-time illuminationApprox. 3.3 days when the air-suspension feature is used for 0.5 hours/day.Approx. 3.3 days when the air-suspension feature is used for 0.5 hours/day.Mass25kg29kg25kg29kgSize (mm)Stroke 350mm type: 280(W)x273(D)x784(H)mmStroke 600mm type: 280(W)x273(D)x1016(H)mmOperating temperature range (recommended)0 − 40˚C (10 − 30˚C)Operating temperature range20 - 80%RH (Must be free from condensation)Storage temperature range-10˚C − 50˚CStorage humidity range5 - 90% RH (Must be free from condensation)*1 The indication accuracy and repeatability represent the values obtained from the height measurement of a at surface using the standard holder with ø5 ball contact point. In the case of diameter, minimum (maximum) value, circle pitch or difference measurement, measuring errors may be larger than the accuracy ratings listed in the table due to variations in measuring force during a scanning measurement, which differs from height measurement.*2 Indicates the value obtained from the measurement of a straight surface placed perpendicular to the the base reference surface using the Lever Head (MLH-321) and Mu-checker (M-411).*3 Requires special communication driver and software. Consult your local Mitutoyo Sales Ofce for details. These can be downloaded from the Mitutoyo web site. http://www.mitutoyo.co.jp/eng/*4 When using a model with the air-suspension feature, it is advisable to use a JIS 1 class, or higher, surface plate. Using on surfaces with scratches or unevenness may prevent the system operating to the specied performance.*5 Battery life depends on the operating conditions. In particular, it is more economical to use the optional AC adapter to power the instrument if the application requires prolonged use of the air-suspension feature.SPECIFICATIONS

元のページ 

page 276

※このページを正しく表示するにはFlashPlayer10.2以上が必要です