MEASURING INSTRUMENTS CATALOG No.E2019
470/608

G-35GLaser Scan MicrometerNon-contact, high-speed, high-precision measurementMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.•2-axis display unit enables 2 items be displayed simultaneously.•Capable of statistical analysis such as: average, maximum value, minimum value, range (max. to min.).•Segment measurement (7 points) or edge measurement (1 to 255 edges) can be selected.•A function to eliminate abnormal values is standard.•100 tolerance values, preset values, or settings can be stored.LSM-5200 Display UnitSERIES 544 — Panel-mount Type•A compact controller which could be used for multi-unit system congurations.•A panel-mount type display unit designed for the LSM-S series.•Analog I/O and RS-232C is standard.LSM-6200 Display UnitSERIES 544 — Multi-function Type1380+172144140.468138 (Aluminum case)197.1(20.5)Front viewRear view68+0.70Dimensions of panel mounting slot (DIN 43 700-144×76)Panel thickness: 1.6 ≤ t ≤ 6 (mm)Mass: 1.4 kgSupport for mounting plateBottom viewt = panel thickness*240.3 + (t–0.6)(4.4)(Aluminum case)Side viewSPECIFICATIONSOrder No.544-071544-072Typemminch/mmDisplay16-digit plus 11-digit fluorescent display, and guide message LEDSegment1 to 7 (1 to 3, transparent) or 1 to 255 edges*1Averaging timesArithmetic average: per 2 to 2048/Moving average: per 32 to 2048 (Arithmetic average is per 16 to 2048 when using 544-531, 544-532)JudgmentSelection from "target value + tolerance", "lower tolerance + upper tolerance", or "7 classes multi-limit tolerance zone".Measurement modeStandby, Single measurement, Continuous measurementStatistical analysisMaximum, Minimum, Average, Dispersion, (S.D)Size335(W)×134(H)×250(D) mmPower supply100 to 240 V AC ±10 %, 40 VA, 50/60 HzStandard I/FRS-232C, Analog I/OOptional I/FDigimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/FOperating environment0 to +40 °C, RH 35 to 85 % (non-condensing)Other functionsNominal setting, sample setting, selection of unnecessary digits, transparent object measurement*2, measurement of odd fluted parts, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position)*1, zero-set/offset, dual measurement (optional)*1 The measuring range will be 0.1 mm to 2 mm in the 1 to 255 edge measurement mode or when activating automatic workpiece detection with 544-531, 544-532. Each function has its combination limit.*2 The measuring range is 50 µm to 2 mm when using 544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office.Note 1: To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE.Note 2: Cannot be connected to 544-495, 544-496.Note 3: Previous models such as 544-451 cannot be connected.SPECIFICATIONSOrder No.544-047Display9 digits plus 8 digits LED, guide message LEDSegment1 to 7 (1 to 3, transparent) or 1 to 255 edges*1Averaging methodArithmetic average: from 4 to 2048; Moving average: from 32 to 2048(Arithmetic average is from 16 to 2048 when using LSM-500S.)JudgmentSelecting from "target value ± tolerance value" or "lower limit/upper limit".Measurement modeStandby, Single measurement, Continuous measurementStatistical analysisCalculation result is output via USB or RS-232C.External dimensions144(W)×72(H)×197.1(D) mmPower supply*324 V DC±10 %, 1.3 A or moreStandard I/FUSB2.0, RS-232C, I/O analogOperating environment 0 to 40 °C, RH 35 to 85 % (non-condensing)Preservation environments−20 to 70 °C, RH 35 to 85 % (non-condensing)Other functionsMeasurement of odd fluted parts, simultaneous measurement, nominal setting, sample setting, selection of unnecessary digits, transparent object measurement*2Automatic workpiece detection (dimension/position detected)*1, abnormal data elimination, mastering, statistical processing (when using USB, RS-232C), output timer, automatic measurement in edge mode, presettingNote that every function is limited in its combination possibilities. See the user manual for details.Mass1.4 kg*1 The measuring range will be 0.1 mm to 2 mm in the 1 to 255 edge measurement mode or when activating the automatic workpiece detection with 544-531, 544-532. Each function has its combination limit.*2 The measuring range is 50 µm to 2 mm when using 544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office.*3 DC24 V external power supply (commercial item) is required separately.Note 1: Cannot be connected to 544-495, 544-496.Note 2: Previous models such as 544-451 cannot be connected.Note 3: For USB communication with a PC, a dedicated device driver is required. For details, contact your local Mitutoyo sales office.Cable space●キーロックCALオフセット統計処理同時測定BUSYRUN+NGGO-NGLD2 ONLD1 ON0+/-123654789L.CALH.CAL読込みシフト測定設定C合否判定オフセット基準値入力単位葦字統計処理PROG.SW.FOOTI/O ANALOGRS-232CREMOTE INTERLOCKSCAN SIG.-1TRANSMITTER-1ID ROM 1A1A6B1B6DI3358012513134281.412113.525012°DIMENSIONSUnit: mmDIMENSIONSUnit: mm

元のページ  ../index.html#470

このブックを見る