MEASURING INSTRUMENTS CATALOG No.E2019
420/608

F-81FMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Thickness GagesSERIES 547, 7Dial Indicator ApplicationsComparison measuring instruments which ensure high quality, high accuracy and reliability.SPECIFICATIONSMetricOrder No.Range (mm)Resolution (mm)Accuracy (μm)Measuring force (N)Remarks547-4010-120.001±33.5 or lessHigh accuracy, carbide point anvil547-3010-100.01±201.5 or lessStandard, ceramic point/anvil547-3210-100.01±201.5 or lessDeep throat, ceramic point/anvil547-3130-100.01±201.5 or lessLens thickness547-3150-100.01±201.5 or lessGroove depth547-3600-100.01±201.5 or lessTube thicknessInch/MetricOrder No.Range (in)ResolutionAccuracyMeasuring force (N)Remarks547-400S/ — 0-0.470.00005 in/0.001 mm±0.0001 in/±3 μm3.5 or lessHigh accuracy, carbide point anvil — /547-526S*0-0.470.0001 in/0.001 mm±0.0002 in/±5 μm1.5 or lessStandard, ceramic point/anvil547-300S/547-500S*0-0.4/0-0.47*0.0005 in/0.01 mm±0.001 in/±20 μm1.5 or lessStandard, ceramic point/anvil547-320S/547-520S*0-0.4/0-0.47*0.0005 in/0.01 mm±0.001 in/±20 μm1.5 or lessDeep throat, ceramic point/anvil547-312S/547-512S*0-0.4/0-0.47*0.0005 in/0.01 mm±0.001 in/±20 μm1.5 or lessLens thickness547-316S/547-516S*0-0.4/0-0.47*0.0005 in/0.01 mm±0.001 in/±20 μm1.5 or lessGroove depth547-361S/547-561S*0-0.4/0-0.47*0.0005 in/0.01 mm±0.001 in/±20 μm1.5 or lessTube thickness* Using ID-SX Digimatic indicator.MetricOrder No.Range (mm)Graduation (mm)Accuracy (μm)Measuring force (N)Remarks73270-10.001±51.4 or lessFine dial reading, ceramic point/anvil73010-100.01±151.4 or lessStandard, ceramic point/anvil73050-200.01±202.0 or lessStandard, ceramic point/anvil73210-100.01±151.4 or lessDeep throat, ceramic point/anvil73230-200.01±222.0 or lessDeep throat, ceramic point/anvil73130-100.01±151.4 or lessLens thickness73150-100.01±151.4 or lessGroove depth73600-100.01±151.4 or lessTube thicknessInchOrder No.Range (in)Graduation (in)Accuracy (in)Measuring force (N)Remarks7326S0-0.050.0001±0.00021.4 or lessFine dial reading, ceramic point/anvil7300S0-0.50.001±0.0011.4 or lessStandard, ceramic point/anvil7304S0-10.001±0.0022.0 or lessStandard, ceramic point/anvil7322S0-10.001±0.0022.0 or lessDeep throat, ceramic point/anvil7312S0-0.50.001±0.0011.4 or lessLens thickness7316S0-0.50.001±0.0011.4 or lessGroove depth7361S0-0.50.001±0.0011.4 or lessTube thicknessNote 1: The dial indicator needs to be reset when replacing a contact point is replaced. Note 2: The stated accuracy of Digimatic indicators does not include an allowance for quantizing error (±1 count).

元のページ  ../index.html#420

このブックを見る