MEASURING INSTRUMENTS CATALOG No.E2019
41/608

A-14AMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Measurement Data Input UnitInput Tool SERIES IT-016U/IT-007RUSB Keyboard Signal Conversion Type IT-016UThe IT-016U, a popular USB input tool that enables easy data recording. Allows you to perform inspection work more efficiently.RS-232C Communication Conversion Type IT-007RInput tool for RS-232C communication best suited for communication control of the software!The IT-016U is equipped with a connector socket for a push-button or switch-foot operation.Control is available by transmitting data request commands via RS-232C.Functional improvements include:•A bigger, easy-to-press data switch. Size increased from ø4 mm to ø18 mm.Durability of the push button increased from 1 million to 10 million operations.•May be used with optional software USB-ITPAK V2.1.Enables efficient routine inspection work, for example, in mass production.For example, production engineers can create communication programs to load the measurement data by transmitting a command from the PC.This product is a compact and low-cost RS-232C communication interface, which is convenient when it is installed in a machine tool or dedicated device to feed back measurement data.Main Specifications of IT-016USupported driver software: Changeable between two typesOutput specification: USB2.0 or USB1.0(1) Stand-alone: HID keyboard device*(2) Using USB-ITPAK V2.1: Virtual COM port (VCP)Communication speed: 12 Mbps (Full Speed)Power supply: USB bus powerUSB2.0 certificateConforms to EMC Directives* This product is compatible with the standard driver software for Windows. No dedicated driver software is required.Specications of IT-007R RS-232C Communication• Output specification: RS-232C compliantCommunication method: Full duplexCommunication speed: 2400 bps (fixed)Bit configuration:Start bit 1 Data length 8 (Most significant bit, 0 (fixed)) Parity, None Stop bit 1Flow control: NoneHome position: DCE (modem definition)• Data format• Data request signalData can be output by transmitting a character from the PC.• Connector specification and power supply from the PCThis product operates while accumulating the power supplied from the PC. A second or more input interval is required.⑤④③②①⑨⑧⑦⑥Pin No.Symbolin/outDescription of functions1(N.C.)—No connection2RXDOUTData output from this product to the PC3TXDINData input from the PC to this product4DTRIN+12 V power supply from the PC*5GND—Ground6DSROUTNot used7RTSIN+12 V power supply from the PC*8CTSOUTNot used9(N.C.)—No connection* "4" and "6", "7" and "8" are connected with each other inside this product.* When connecting to a sequencer, a power supply is required. Input voltage: Supplied in the range 6 V - 16 V Power supply terminal: Supplied to pins 4 and 7IT-016U/IT-007R System CongurationSystem Environment• Hardware:PC with USB socket (Type A)• Supporting OS:• Software:Programs supporting keyboard input(Excel, Word, memo pad, etc.)USB-ITPAK V2.1 (optional)System Environment• Hardware:PC or sequencer with a serial port (D-sub 9 pin)• Software:A program compatible with the RS-232C communication (such as a hyper terminal) is required.USB socket(Type A)Connection portD-sub 9 pinSerial portFoot switch (optional)Connector shapeABCDEFGConnect the Digimatic connector to the gageConnect the unit to a USB port of the PCDigimatic gageInput toolConnecting cable (optional)Connecting cable (optional)PCSwitch box (optional)Foot switch (optional) Gage selector 3 (optional)937179T939039Connecting cable 2 mRefer to pages A-25 and A-26 for details.Connector7 types (A to G) + 4 L typesUSB keyboard signal conversion model Model: IT-016U 264-016-10Data output is available by transmitting data request commands from the PC.RS-232C communication conversion typeModel: IT-007R264-007(2)(1)(2)This selector can connect up to 3 measuring gages and switching is available with the slide switches without changing connecting cables. Connecting cable (length: 1 m) between two input tools is a standard accessory (936937).Connect the unit to a serial port of the PCWindows 98SEWindows MeWindows 2000Windows XPWindows VistaWindows 7Windows 8Windows 8.1Windows 10CBFDigimatic indicatorDigimatic micrometerRefer to pages A-25 and A-26 for details of Digimatic ports and connectors.Digimatic caliper(1) When data output(2) Error code outputD1D2D3D4D5D6D7D8D9D10D11D12D13"0 1 A" (xed)Signs, "+" or "–"Output order —>CRData parts (Floating decimal point)D1D2D3D4"9 1" (xed)Error code No.1: No data input2: Loaded data with format other than speciedExample of format Display Output data 0.123 —> 01A + 0000.123CR —>−0.1234 —> 01A − 000.1234CRCR(1)Cable length: 1 m or 2 mGAGEDATAIT-016UIT-007RThe HID keyboard device (standard driver software for Windows) is automatically recognized when connected to a USB port.* HID (Human Interface Device)(1)(2)IT-016UFoot switch

元のページ  ../index.html#41

このブックを見る