MEASURING INSTRUMENTS CATALOG No.E2019
355/608

F-16FMitutoyo reserves the right to change any or all aspects of any product specication, including prices, designs and service content, without notice.Functions• Calculation f (x’) = Ax’ + B + Cx’ –1 (x’ = x + offset)• Peak detection (MAX/MIN)• Runout value Hold (difference between max. and min. value)• Peak detection sampling rate (Switchable)10 times/s (FAST Mode OFF)50 times/s (FAST Mode ON)• Zero-setting (INC system)• Preset (ABS system)• Tolerance judgment (P1, P2, P3, and INC can be stored)• Analog bar resolution selectable• Key lock• Display hold (when external device is connected)• Data output• External PC setting input• Display rotation (330°)• Low battery voltage alarm display• Error alarm display• Resolution switching** Since the calculation resolution is one micrometer (0.001 mm), using sub-micrometer resolution settings may result in the 4th-place digit being unreliable, particularly when B is set to a very low value and C = 0. It does not change at all with certain combinations of calculation coefcient (for example, A = 1, B = C = 0). The 3rd-place digit representing micrometers (if displayed) is always reliable.Optional Accessories• Lifting Lifting lever21EZA198 (ISO/JIS/DIN Type), 21EZA199 (ASME/ANSI/AGD Type) Lifting knob21EZA105 (ISO/JIS/DIN Type), 21EZA150 (ASME/ANSI/AGD Type) Lifting cable540774• SPC Cable: 905338 (1 m) 905409 (2 m)• USB Input Tool Direct (2 m): 06AFM380F• Input Tool Series IT-016U (USB Keyboard Signal Conversion Type): 264-016-10 IT-007R (RS-232C Communication Conversion Type): 264-007 Refer to page F-66 for details.• Connecting Cables for U-WAVE-T (160 mm): 02AZD790F For foot switch: 02AZE140F Refer to page F-66 for details.• Digimatic Mini-Processor DP-1VA LOGGER: 264-505• Parameter setup kit: 21EZA313 Note: Parameter setting software (can be downloaded for free from the Mitutoyo website) is also required.• Contact points for Mitutoyo’s dial indicators (Refer to pages F-57 to F-60 for details.)• Measuring stands (Refer to pages F-84 to F-92 for details.)Resolution (mm)0.00020.0050.10.00050.010.20.0010.020.50.0020.051Resolution (inch)0.000010.00020.0050.000020.00050.010.000050.0010.020.00010.0020.05An inspection certicate is supplied as standard. Refer to page U-11 for details.Products equipped with the measurement data output function can be connected to the measurement data network system MeasurLink (refer to page A-5 for details).ABSOLUTE Digimatic Indicator ID-CSERIES 543 — Calculation Type• The ABS (absolute) scale restores the last origin position*1 automatically when the indicator is turned on, and realizes high reliability by eliminating over-speed errors.• By using the parameter setup kit (optional) and the dedicated software, the functions and the parameters can be congured using a computer.*1 Regarding origin setting, refer to “Origin Setting of Digimatic Indicators” on page F-25.Digimatic IndicatorsComparison measuring instruments which ensure high quality, high accuracy and reliability.SPECIFICATIONSMetricOrder No.Range (mm)Resolution (selectable)Accuracy*2 (mm)Measuring force (N)Power supplyBattery life (normal use)*5Net weight (g)Overall*3HysteresisRepeatability543-340B12.712 steps*50.0030.0020.0021.5 or lessCR2032 × 1 pc.Approx. 1 year170543-590B25.41.8 or less*4190543-595B50.80.0062.3 or less*4260Inch/MetricOrder No.RangeResolution (selectable)Accuracy*2Measuring force (N)Power supplyBattery life (normal use)*5Net weight (g)Overall*3HysteresisRepeatability543-341B0.5 in/12.7 mm12 steps*5±0.0001 in /0.003 mm0.0001 in /0.002 mm0.0001 in /0.002 mm1.5 or lessCR2032 × 1 pc.Approx. 1 year170543-342B543-591B1 in/25.4 mm1.8 or less*4190543-592B543-596B2 in/50.8 mm±0.00025 in /0.006 mm2.3 or less*4260543-597B*2 Quantizing error of ±1 count is excluded. Valid for resolution set to 0.001 mm/0.00005 inch and coefcients A=1, B=0 and C=0.*3 Overall magnication and linearity.*4 Applies for a spindle orientation between the spindle pointing vertically downward to the spindle horizontal.*5 Applies only if not connected to a data processor. Battery life depends on use of the indicator. Use the above value as a guide only.Note: Flat back type only.• Calculation function operates on spindle displacement. Entering the appropriate formula factors for a xture dedicated to the application enables direct measurement readout, thereby eliminating any need for the conversion tables previously needed for those applications where xtures are typically used.• Simple operation of many functions with ve buttons and status icons.• Wide LCD and new analog bar graph are now standard on all models.543-342B ISO/JIS type ASME/ANSI/AGD type

元のページ  ../index.html#355

このブックを見る