MEASURING INSTRUMENTS CATALOG No.E2016
622/682

M-3MHardness Testing MachinesStart quality control from the material — Mitutoyo's hardness testing machines can handle itMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.HM-200SERIES 810 — Micro Vickers Hardness Testing MachinesOptional Accessories19BAA058:Diamond indenter for Vickers (For HM-210 series)19BAA059:Diamond indenter for Vickers (For HM-220 series)19BAA061:Diamond indenter for Knoop (For HM-210 series)19BAA062:Diamond indenter for Knoop (For HM-220 series)19BAA001:Hardness standard block 100HMV 19BAA002:Hardness standard block 200HMV 19BAA003:Hardness standard block 300HMV 19BAA004:Hardness standard block 400HMV 19BAA005:Hardness standard block 500HMV 19BAA006:Hardness standard block 600HMV 19BAA007:Hardness standard block 700HMV 19BAA008:Hardness standard block 800HMV 19BAA009:Hardness standard block 900HMV 19BAA010:Hardness standard block 40HMV 810-017:Special vise (opening width 100mm)810-013:Sheet specimen table810-014:Thin specimen table (horizontal type) 810-015:Thin specimen table (vertical type) 810-019:Tilting specimen table 810-020:Adjustable specimen holder 810-018:Rotary table 810-084:Rotatable adjustable specimen table810-085:Sheet specimen table 810-095:Rotary tilting specimen table375-056:Objective micrometer (for calculation of dimension ratio for a pixel of CCD camera)810-650-1:Resin mold specimen table ø25.4810-650-2:Resin mold specimen table ø30810-650-3:Resin mold specimen table ø31.75810-650-4:Resin mold specimen table ø38.1810-650-5:Resin mold specimen table ø4002ATE760:Dedicated table (for testing machine, PC) 810-641:Vibration Isolator (for testing machine)•Introduction of electromagnetic force generation into the loading mechanismThe latest electromagnetic force motor used in the loading mechanism enables the test force to be freely selected (see test force specications) over the wide range of 0.4903mN to 19610mN. It is also possible to freely set the loading time and duration time. Now your desire for absolute control over the indentation size in Vickers hardness testing can be satised. The HM-200 series always offers the test force most appropriate for the specimen material and shape.Note: Changing the test force may change the hardness value obtained due to material non-homogeneity. Surface treatment, such as Nitriding, can also produce the same effect because the material hardness changes with depth, and indentation depth depends on the test force.•Newly-designed optical systemThe new HM Plan series objective lenses are optimized for measuring characteristic indentation images. The lineup includes 6 types of long working distance objectives: 10X, 20X, 50X and 100X for measuring indentation images, and 2X and 5X for enabling wide-range measurement around indentations. LEDs, which have a longer life, produce less heat, consume less power and are more energy efcient than incandescent bulbs, are employed for the illumination system.System A(HM-210A/220A)Refer to the Hardness Testing Machines (Catalog No. E17001) for more details.An inspection certicate is supplied as standard. Refer to page X for details.SPECIFICATIONSOrder No.810-401, 810-404810-406, 810-409ModelHM-210HM-220Applicable standardsJIS B 7725, ISO 6507-2Test forcemN98.07196.1294.249.03980.70.49030.98071.9612.9424.9039.80719.6129.4249.0398.07(gf)102030501000.050.10.20.30.5123510mN1961294249039807ー196.1294.2490.3980.7196129424903980719610ー(gf)2003005001000ー20305010020030050010002000ーArbitrary test force 1 type [Default: 245.2mN (25gf)]Test force controlElectromagnetic generation of force (force motor) and automatic control (load, duration, unload)Indenter shaft unitUp to 2 pcs. mountable (one indenter shaft unit with Vickers indenter is mounted as standard)Objective lens unitUp to 4 pcs. mountable (one standard lens 50X mounted as standard)Resolution of diagonal length of an indentationObjective lens less than 50X: 0.1μm (Objective lens more than 50X: 0.01μm)Turret driveMotor-driven and manual operationSpecimen dimensionsSystem A/B: height 133mm, depth 160mm (when using manual XY stage 25X25)System C: height 112mm, depth 160mm, System D: height 72mm, depth 160mmControl panelBuilt-in touch panel, 5.7" Color LCD (HM-210A/220A for System A), Control software (PC for System B/C/D) Functions*1Calculation of Vickers / Knoop*2 hardness, and ceramic fracture toughness based on IF method (JIS R1697),3 display format (standard, list, simple), GO/NG judgment, test condition guide, curve and user correction, hardness corresponding value, statistics calculationOutputDigimatic, serial, USB2.0 series A (for memory)*1, USB2.0 B Type (for system communication)External dimensions (excluding protrusions and stage); Main unit mass System A: 315(W)×671(D)×595(H)mm/38.5kgSystem B/C/D: 315(W)×586(D)×741(H)mm/37.4kgPower supply (main unit)AC100V 50/60HzSystem A: 31W System B/C/D: 30WAC100V 50/60HzSystem A: 44W System B/C/D: 43WPower supply*3 (Control unit)AC100V 50/60Hz67W*810-401, 810-406: System A, 810-404, 810-409: System B/C/D *1: Functions for System A. *2: For Knoop hardness test, Knoop indenter (optional) is required. *3: Supplied only for System C/D.

元のページ 

page 622

※このページを正しく表示するにはFlashPlayer10.2以上が必要です