MEASURING INSTRUMENTS CATALOG No.E2016
563/682

K-10KMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.The 2D micro form is analyzable from the contour data obtained via the non-contact displacement sensor, PFF, and WLI. A wide variety of surface textures are analyzable including 3D displays such as lling between contour lines and shading.Micro form analysis screen ShadingWire frameExample of cut surface analysisFORMTRACEPAK-APFORMTRACEPAK-PRO Main Unit SpecicationsGradeModel namePROPRO3QVH Apex/ACCEL○○Hyper QVH/QVH STREAM ○̶Refer to the table in the lower part of page K-4 for the details of grade.Form assessment softwareSafety Precautions for Laser BeamThese systems uses a low-power invisible laser beam (780nm) which corresponds to Class 1 (invisible light) of JIS C 6802 "Safety Standard of Laser Radiation Products". The class 1 laser warning label as shown above is attached to the main unit.CLASS 1 LASER PRODUCTQV ACCEL HYBRID TYPE1ModelQVH1 ACCEL 808QVH1 ACCEL 1010QVH1 ACCEL 1212QVH1 ACCEL 1517Optical systemPROPRO3PROPRO3PROPRO3PROPRO3Order No.365-315365-316365-335365-336365-355365-356365-375365-376Measuring range by vision probe (X×Y×Z)800×800×150mm1000×1000×150mm1250×1250×100mm1500×1750×100mmMeasuring range by displacement sensor (X×Y×Z)680×800×150mm880×1000×150mm1130×1250×100mm1380×1750×100mmMeasuring Accuracy*1 (Vision)E1X,E1Y(1.5+3L/1000)µm(2.2+3L/1000)µmE1Z(1.5+4L/1000)µm(2.5+5L/1000)µmE2XY(2.5+4L/1000)µm(3.5+4L/1000)µmDisplacement sensor Measuring Accuracy*1E1Z(2.5+4L/1000)µm(3.5+5L/1000)µmDisplacement sensor Detecting range of probe itself±0.5mmVertical resolving power10nmSpot diameterAbout ø2µmWorking distance (including the collision sensor)5mmOperating Temperature rangeAmbient temperature20±1°CTemperature variation2˚C / 8H*1: Determined by Mitutoyo’s inspection method. L is the measured length (mm). The optical condition for accuracy assurance is to be (QV-HR2.5X or QV-SL2.5X) + Low magnification of the tube lens. Other specifications are the same as those of the QV ACCEL. For details, refer to page K-7.QV STREAM PLUS HYBRID TYPE1ModelQVH1 STREAM 302QVH1 STREAM 404QVH1 STREAM 606Optical systemPROPROPROOrder No.365-172365-182365-192Imaging DeviceB&W CCDIllumination unitCo-axial LightColor LEDTransmitted LightBlue LEDPRLColor LEDMeasuring Accuracy*1 (Vision)E1X,E1Y(1.5+3L/1000)µmE1Z(1.5+4L/1000)µmE2XY(2+4L/1000)µmDisplacement sensor Measuring Accuracy*1E1Z(1.5+4L/1000)µmOperating Temperature rangeAmbient temperature20±1°CTemperature variation2˚C / 8H*1: Determined by Mitutoyo’s inspection method. L is the measured length (mm). The optical condition for accuracy assurance is to be (QV-HR2.5X or QV-SL2.5X) + Middle magnification of the tube lens. Other specifications are the same as those of the QVH1 Apex. For details, refer to above table.QV Apex HYBRID TYPE 4ModelQVH4 Apex 302QVH4 Apex 404QVH4 Apex 606Optical systemPROPROPROOrder No.365-413365-433365-453Measuring range by vision probe (X×Y×Z)300×200×200mm400×400×250mm600×650×250mmMeasuring range by displacement sensor (X×Y×Z)176×200×200mm276×400×250mm476×650×250mmResolution of scale / Scale type0.1μm / Linear EncoderObservation Unit*1PPT1X-2X-6XImaging DeviceB&W CCDB&W CCDB&W CCDIllumination unit*2Co-axial LightWhite LEDTransmitted LightWhite LEDPRLWhite LEDMeasuring Accuracy*3 (Vision)E1X,E1Y(1.5+3L/1000)µmE1Z(1.5+4L/1000)µmE2XY(2+4L/1000)µmDisplacement sensor Accuracy E1Z(1.5+4L/1000)µmDisplacement sensor Detecting range of probe itself±0.6mmVertical resolving power25nmSpot diameterAbout ø4µmWorking distance (including the collision sensor)21.0mmOperating Temperature rangeAmbient temperature20±1°CTemperature variation2˚C / 8HStage glass size399×271mm493×551mm697×758mmMaximum stage loading*420kg40kg50kgMain unit external dimensions859×951×1609mm1027×1407×1778mm1309×1985×1794mmMain unit mass (including the sub-base)370kg589kg1460kg*1: The specific combination of 1X, 2X and 4X or 1X, 2X, 4X and 6X is available by custom order.*2: The color LED lighting or halogen lighting specification is available by custom order.*3: Determined by Mitutoyo’s inspection method. L is the measured length (mm). The optical condition for accuracy assurance is to be (QV-HR2.5X or QV-SL2.5X) + Middle magnification of the tube lens.*4: An excessively biased or concentrated load is excluded.* Append "S" to the end of code number to order a QV machine compatible with ISO10360-7:2011 Accuracy Assurance. (PRO machine only)Hyper QV HYBRID TYPE4ModelHyper QVH4 302Hyper QVH4 404Hyper QVH4 606Optical systemPROPROPROOrder No.365-416365-436365-456Resolution of scale / Scale type0.02μm / Linear EncoderMeasuring Accuracy*1 (Vision)E1X,E1Y(0.8+2L/1000)µmE1Z(1.5+2L/1000)µmE2XY(1.4+3L/1000)µmDisplacement sensor Accuracy E1Z(1.5+2L/1000)µmOperating Temperature rangeAmbient temperature18 ~ 23°CTemperature variation0.5˚C / 1H and 1˚C / 24HTemperature compensation functionAutomaticMaximum stage loading*215kg30kg40kg*1: Determined by Mitutoyo’s inspection method. L is the measured length (mm). The optical condition for accuracy assurance is to be (QV-HR2.5X or QV-SL2.5X) + Middle magnification of the tube lens.*2: An excessively biased or concentrated load is excluded. Other specifications are the same as those of the QVH4 Apex.For details,refer to the table above.

元のページ 

page 563

※このページを正しく表示するにはFlashPlayer10.2以上が必要です