MEASURING INSTRUMENTS CATALOG No.E2016
535/682

J-14JMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.MF-U series (Motor-Driven Z-axis/Motor-Driven)SERIES 176 — Universal Measuring MicroscopesSpecications for Motor-Driven Z-axis MF-U SeriesBF(brighteld)Model No.MF-UJ2017DMF-UJ3017DMF-UJ4020DOrder No.176-894*1176-895*1176-896*1BD(brighteld/darkeld)Model No.MF-UK2017D MF-UK3017DMF-UK4020DOrder No.176-897*1176-898*1176-899*1Observation imageBF (Bright eld), DF (Dark eld) (MF-UK models only), Polarization, Differential Interference Contrast (DIC) / Erect imageEyepiece (optional) Adjustable diopter10X (eyepiece eld number: 24, two eyepieces provided as standard), 15X, 20X Turret (required)Bright-eld (BF)Adjustable manual turret or adjustable power turret (Select one.) Bright-eld/dark-eld (BD)Manual turret or power turret (Select one.) Objective (optional)Bright-eld (BF)M Plan Apo, M Plan Apo SL, G Plan Apo series Bright-eld/dark-eld (BD)BD Plan Apo, BD Plan Apo SL series Illumination unit (One of the two options must be selected.)LEDTransmitted: Telecentric, built-in aperture diaphragm, white LED light source, stepless brightness adjustment, equipped with cooling fanReected: Kohler illumination with adjustable aperture diaphragm, white LED light source, stepless brightness adjustment , equipped with cooling fan Control unit: Power switch (main switch), AC power supply input connector (100 to 240V) Halogen Transmitted: Telecentric, built-in aperture diaphragm, 12V/50W halogen lamp, stepless brightness adjustment, with cooling fanReected: BF/BD Kohler illumination with adjustable aperture diaphragm, 12V100W or 12V15W halogen lamp (selectable), external ber illumination, stepless brightness adjustmentControl unit: Power switch (main switch), AC power supply input connector (100 to 240 V) Vision AF *2YesLaser auto focus (LAF) ———StageMeasuring range200×170mm300×170mm400×200mmQuick release mechanismFitted to X and Y axesZero set switchFitted to X and Y axesZ axisMax. workpiece height220mmFeed mechanismMotor drive (measuring speed: max. 20mm/s) Measuring accuracy*3 (X and Y axes, when not loaded)(2.2 + 0.02L)μm L: measuring length (mm) Digital displayMinimum reading1/0.5/0.1μm .0001”/.00005”/.00001” switchableDisplay axesX, Y and Z FunctionsZero-setting, direction switching Specications for Motor-Driven MF-U SeriesMotorizedMotorized LAF BF(brighteld)Model No.MF-UG2017DMF-UG3017DMF-UG4020DMF-UE2017DMF-UE3017DMF-UE4020DOrder No.176-784*1176-785*1176-786*1176-790*1176-791*1176-792*1BD(brighteld/darkeld)Model No.MF-UH2017DMF-UH3017DMF-UH4020DMF-UF2017DMF-UF3017DMF-UF4020DOrder No.176-787*1176-788*1176-789*1176-793*1176-794*1176-795*1Observation imageBF (Bright eld), DF (Dark eld) (MF-UH and MF-UF models only), Polarization, Differential Interference Contrast (DIC) / Erect imageEyepiece (optional) Adjustable diopter10X (eyepiece eld number: 24, two eyepieces provided as standard), 15X, 20X Turret (required)Bright-eld (BF)Adjustable manual turret or adjustable power turret (Select one.) Manual turret with BF sensor, adjustable power turret*1 Bright-eld/dark-eld (BD)Manual turret or power turret (Select one.) Manual turret with BD sensor, power turret*1 Objective (optional)Bright-eld (BF)M Plan Apo, M Plan Apo SL, G Plan Apo series Bright-eld/dark-eld (BD)BD Plan Apo, BD Plan Apo SL series Illumination unit (One of the two options must be selected.)LEDTransmitted: Telecentric, built-in aperture diaphragm, white LED light source, stepless brightness adjustment, equipped with cooling fanReected: Kohler illumination with adjustable aperture diaphragm, white LED light source, stepless brightness adjustment , equipped with cooling fan Control unit: Power switch (main switch), AC power supply input connector (100 to 240V) Halogen Transmitted: Telecentric, built-in aperture diaphragm, 12V/50W halogen lamp, stepless brightness adjustment, with cooling fanReected: BF/BD Kohler illumination with adjustable aperture diaphragm, 12V100W or 12V15W halogen lamp (selectable), external ber illumination, stepless brightness adjustmentControl unit: Power switch (main switch), AC power supply input connector (100 to 240 V) Vision AF *2YesLaser auto focus (LAF) ———✓✓✓StageMeasuring range200×170mm300×170mm400×200mm200×170mm300×170mm400×200mmFeed mechanismMotordrive (Maximum measuring speed: 40mm/s)Z axisMax. workpiece height220mmFeed mechanismMotordrive (Maximum measuring speed: 20mm/s)Measuring accuracy*3 (X and Y axes, when not loaded)(2.2 + 0.02L)μm L: measuring length (mm) Digital displayMinimum reading1/0.5/0.1μm .0001”/.00005”/.00001” switchableDisplay axesX, Y and Z FunctionsZero-setting, direction switching *1: To denote your AC power cable add the following sufxes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No sufx are required for PSE.*2: Vision Unit and an image AF cable are separately required.*3: Measuring method complies with JIS B7153.•Motor-driven Z-axis model of the MF-U series and Motor-driven X-, Y-, and Z-axes model of the MF-U series. •Using the optional Vision Unit enables the image AF function.•Illumination unit (reected/transmitted) can be selected from a high-intensity LED or halogen bulb (required).•Variable aperture diaphragm (reected/ transmitted) allows observation measurement while suppressing light diffraction.• A wide variety of optional accessories including various digital CCD cameras are offered. •Proven high-NA objectives from the FS optical system (long working distance type).•Integration of metallurgical and measurement microscope functions provides high-resolution observation and a high-accuracy measurement solution.•High-magnication observation up to 4000X.•MF-UE/UF is capable of performing Laser AF.The standard Lase AF function is equipped with the tracking function which keeps a focus even when the stage is moving.MF-UE2017D• The turret, objectives and illumination unit are optional accessories.MF-UJ2017D• The turret, objectives and illumination unit are optional accessories.For replacement for reflected illumination (from separate light source)*4Standard: Halogen bulb (12V, 100W) (No.517181)High-intensity bulb (12V, 100W) (No.12BAD602)Bulb replacement for transmitted/reflected illumination Standard: Halogen bulb (12V, 50W) (No.513667)Bulb life: 1,100 hours*4: At the time of purchase, a standard bulb and a high-intensity bulb are provided. (Only for the Reflected illumination models.)

元のページ 

page 535

※このページを正しく表示するにはFlashPlayer10.2以上が必要です