MEASURING INSTRUMENTS CATALOG No.E2016
533/682

J-12JMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.MF series (Motor-Driven Z-axis/Motor-Driven)SERIES 176 — Measuring MicroscopesSpecications for Motor-Driven Z-axis MF SeriesModel No.MF-J2017DMF-J3017DMF-J4020DOrder No. 176-891*1 176-892*1 176-893*1Observation imageBF (Bright eld)/Erect imageEyepiece (optional) Adjustable diopter10X (eyepiece eld number: 24), 15X, 20X Note: Monocular - one 10X eyepiece provided as standard; Binocular - two 10X eyepieces provided as standard Objective (optional)ML objective 3X (provided as standard), 1X, 5X, 10X, 20X, 50X, 100XIllumination unit (One of the two options must be selected.)LED Transmitted: Telecentric, built-in aperture diaphragm, white LED light source, stepless brightness adjustment, equipped with cooling fanReflected: Kohler illumination with adjustable aperture diaphragm, white LED light source, stepless brightness adjustment Control unit: Power switch (main switch), AC power supply input connector (100 to 240V)Halogen Transmitted: Telecentric, built-in aperture diaphragm, 12V/50W halogen lamp, stepless brightness adjustment, with cooling fanReflected: Kohler illumination with adjustable aperture diaphragm, 12V50W halogen lamp, stepless brightness adjustment with cooling fanControl unit: Power switch (main switch), AC power supply input connector (100 to 240V) Vision AF *2YesStageMeasurement range200×170mm300×170mm400×200mmQuick release mechanismFitted to X and Y axesZero set switchFitted to X and Y axesZ axisMax. workpiece height220mmFeed mechanismMotordrive (Maximum measuring speed: 20mm/s)Measuring accuracy *3 (X and Y axes, when not loaded)(2.2 + 0.02L)μm L: measuring length (mm) Digital displayMinimum reading1/0.5/0.1μm .0001”/.00005”/.00001” switchableDisplay axesX, Y and Z axes FunctionsZero-setting, direction switching *1: To denote your AC power cable add the following sufxes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No sufx are required for PSE.*2: Vision Unit and an image AF cable are separately required.*3: Measuring method complies with JIS B7153.Specications for Motor-Driven MF SeriesModel No.MF-G2017DMF-G3017DMF-G4020DOrder No. 176-781*1 176-782*1 176-783*1Observation imageBF (Bright eld)/Erect imageEyepiece (optional) Adjustable diopter10X (eyepiece eld number: 24), 15X, 20X Note: Monocular - one 10X eyepiece provided as standard; Binocular - two 10X eyepieces provided as standard Objective (optional)ML objective 3X (provided as standard), 1X, 5X, 10X, 20X, 50X, 100XIllumination unit (One of the two options must be selected.)LED Transmitted: Telecentric, built-in aperture diaphragm, white LED light source, stepless brightness adjustment, equipped with cooling fanReflected: Kohler illumination with adjustable aperture diaphragm, white LED light source, stepless brightness adjustment Control unit: Power switch (main switch), AC power supply input connector (100 to 240V)Halogen Transmitted: Telecentric, built-in aperture diaphragm, 12V/50W halogen lamp, stepless brightness adjustment, with cooling fanReflected: Kohler illumination with adjustable aperture diaphragm, 12V50W halogen lamp, stepless brightness adjustment with cooling fanControl unit: Power switch (main switch), AC power supply input connector (100 to 240V) Vision AF *2YesStageMeasurement range200×170mm300×170mm400×200mmFeed mechanismMotordrive (Maximum measuring speed: 40mm/s)Z axisMax. workpiece height220mmFeed mechanismMotordrive (Maximum measuring speed: 20mm/s)Measuring accuracy *3 (X and Y axes, when not loaded)(2.2 + 0.02L)μm, L: measuring length (mm) Digital displayMinimum reading1/0.5/0.1μm .0001”/.00005”/.00001” switchableDisplay axesX, Y and Z axes FunctionsZero-setting, direction switching *1: To denote your AC power cable add the following sufxes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No sufx are required for PSE.*2: Vision Unit and an image AF cable are separately required.*3: Measuring method complies with JIS B7153.•Motor-driven Z-axis model of the MF series and Motor-driven X-, Y-, and Z-axes model of the MF series. •Using the optional Vision Unit enables the image AF function.•Illumination unit (reected/transmitted) can be selected from a high-intensity LED or halogen bulb (required). •Variable aperture diaphragm (reected/ transmitted) allows observation measurement while suppressing light diffraction.•A wide variety of optional accessories including various digital CCD cameras are offered.•ML series, high-NA objectives that are specially designed for the MF series. (long working distance type)•High-magnication observation up to 2000X.MF-G2017D• The binocular tube (eyepiece) and illumination unit are optional accessories.MF-J2017D• The binocular tube (eyepiece) and illumination unit are optional accessories.Bulb replacement for transmitted/reflected illumination Standard: Halogen bulb (12V, 50W) (No.513667)Bulb life: 1,100 hoursBulb replacement for transmitted/reflected illumination Standard: Halogen bulb (12V, 50W) (No.513667)Bulb life: 1,100 hours

元のページ 

page 533

※このページを正しく表示するにはFlashPlayer10.2以上が必要です