MEASURING INSTRUMENTS CATALOG No.E2016
479/682

G-48GMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.ø3.1 (Measuring position)12-M3Measuring range80Cable space18011256098100502264760120101188236552.540382851805282021110.515.51010010150839710010017213.5SERIES 544 Laser Scan Micrometer (Display Unit Integrated Model)LSM-9506•High accuracy of ±2.5μm, integrated display unit with many functions equivalent to the multi-function display unit.Optional Accessories• Standard calibration gage set (ø1, ø60): 02AGD170Unit: mmDIMENSIONSRefer to the Laser Scan Micrometer (Catalog No. E13004) for more details.SPECIFICATIONSOrder No.544-115*544-116**Typemminch/mmMeasuring range0.5 to 60mm.02” - 2.36”/0.5 - 60mmResolution0.05 to 100μm (selectable).000002” - .005/0.00005 - 0.1mmRepeatability*1±0.6μm (±.00003")Accuracy*2 (20°C)±2.5μm (±.0001")Positional error*3(optical axis/scanning direction)±2.5μm (±.0001")L: Displacement between workpiece center and optical axis centerMeasuring range*4±5x60mm (±.2x2.36")Scanning rate1600 scans/sLaser wavelength650nm (Visible)*5Laser scanning speed226m/s (8900" / s)Display unit16-digit dot matrix (upper column) + 7 segment 11-digit (lower column) ,guidance LEDsStandard interfaceRS-232C, Digimatic code output unit (1ch)Optional interfaceNoPower supplyAC100V-240V ±10%, 40VA, 50/60HzOperating environment0 to 40°C, RH 35 to 85% (no condensation)*1: Determined by the value of ±2 (: standard deviation) when measuring ø10mm at the interval of 0.32 sec. (average 512 times).*2: Center of the measuring range for cylindrical workpieces outside diameter.*3: D=Difference in diameter between the master gage and workpiece (Unit: mm)*4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5: FDA Class II (544-116-1A)/IEC Class 2 (Allmodels except 544-116-1A) semiconductor laser for scanning (Maximum power: 1.0mW)* To denote your AC power cable add the following suffixes to the order No.: D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE.** To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE.Laser safetyMitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC60825-1 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

元のページ 

page 479

※このページを正しく表示するにはFlashPlayer10.2以上が必要です