MEASURING INSTRUMENTS CATALOG No.E2016
474/682

G-43GLaser Scan MicrometerNon-contact, high-speed, high-precision measurementMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.8-M342645310.515.52250208410457.523070min12339683434*71048818.5404011040.538.5309.59.514.59.51506404015773ø3.1 hole, depth 6(Measuring position)Signal cableCable spaceRelay cableEmission UnitBaseMax. 100Measuring rangeReception UnitMeasuring positionM4, depth 8 (×3)M4, depth 8 (×3)To Reception Unit(Cable length 0.6m)ø3.1 hole, depth 6ø3.1 hole, depth 6Dimension when disconnected (bottom view)Emission Unit: 0.7kgReception Unit: 0.4kgBase: 0.3kgSignal cable (5m): 0.5kg*7: Extendable up to 66mm.SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-501S•Provides ultra-high accuracy of ±0.5μm over the entire measuring range (0.05 to 10mm).•Narrow range accuracy of ±(0.3+0.1D)μm for high precision measurement.•Ultra-high speed measurement of 3200 scan/sec.Suitable for high speed lines or in applications subject to vibration.Optional Accessories• Multifunctional display unit, LSM-6200:• Easy-to-operate display unit, LSM-5200: • Standard calibration gage set (ø0.1, ø10.0) : 02AGD120• Wire guiding pulley: 02AGD210• Adjustable workstage: 02AGD400• Air blower: 02AGD230• Workstage: 02AGD270• Extension signal cableSPECIFICATIONSOrder No.544-533544-534Applicable laser standardsJISIEC, FDAUser's ManualJapanese versionEnglish versionMeasuring range0.05 to 10mmResolution0.01 to 10μm (selectable)Repeatability*1±0.04μmAccuracy*2 (20°C)Whole range±0.5μmSmall range±(0.3+0.1D)μm*3Positional error*4±0.5μmMeasuring range*52×10mm (ø0.05 to ø0.1mm) 4×10mm (ø0.1 to ø10mm)Scanning rate3200 scans/sLaser wavelength650nm (Visible)Laser scanning speed113m/sOperating environmentTemperature0 to 40°CHumidityRH 35 to 85% (no condensation)Protection LevelIP64*6*1: Determined by the value of ±2 (: standard deviation) when measuring ø10mm at the interval of 0.32 sec. (average 1024 times).*2: Center of the measuring range for cylindrical workpieces outside diameter.*3: D=Difference in diameter between the master gage and workpiece (Unit: mm)*4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction.*5: The area given by [optical axis direction]×[scanning direction].*6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.Unit: mmDIMENSIONSRefer to the Laser Scan Micrometer (Catalog No. E13004) for more details.Order No.Cable length02AGN780A5m02AGN780B10m02AGN780C15m• Extension relay cableOrder No.Cable length02AGC150A1mLaser safetyMitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC60825-1 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.Order No.Remarks544-046Japanese user's manual544-047English user's manualOrder No.Display typeRemarks544-071Japanese mm/EJapanese user's manual544-071*English mm/EEnglish user's manual544-072*English mm/inch* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."

元のページ 

page 474

※このページを正しく表示するにはFlashPlayer10.2以上が必要です