MEASURING INSTRUMENTS CATALOG No.E2016
470/682

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.GG-39Optional Accessories• I/O output connector: 02ADB440• D-EV external unit: 02ADD400• SPC cable, 0.5m: 02ADD950• SPC cable, 1m: 936937• SPC cable, 2m: 965014Note 1: To perform calibration a D-EV display unit is required. At least one D-EV unit is required when using multiple EV-16A.Note 2: As a power supply is not supplied as standard. An appropriate power supply with a current capacity of 1A or more must be provided for each EV-16A.Refer to Catalog No. E13003 (Mu-checker) for more details.SPECIFICATIONSOrder No.519-335Number of gage inputsSixQuantizing error±1 LSDDisplay range (mm)±2.000, ±0.200Resolution (mm)0.001, 0.0001Display processing8 digits for parameters (display setting), 1 for error displayError messagingPower supply voltage error, Gage error, etc.External displayDedicated external display unit D-EV (optional) can be connectedNumber of input switches4Input switch functionMeasurement mode switching, Parameter settingsI/O Tolerance judgment output1 to 6 gages (L1, L2, L3), open-collectorBCD outputParallel BCD output (positive/negative-true logic), open-collectorSegment outputA function to enable only output from the terminal corresponding to the counting values, open-collectorControl outputNormal operation signal (NOM), open-collectorControl inputOutput channel designation (segment, in BCD mode), presetting, peak value clear, range changeover (at segment output), holding counting value, open-collector or no-voltage contact signal (with/without contact point)InterfaceRS-232CMeasurement data output and control input, EIA RS-232C-compatibleUse cross cables for home position DTE (terminal definition)RS linkMax. connected units: 10 (6 when using EF counter)Connecting cable length: Max. 10m (sum of link cable length)Data transfer time: 1.1 sec./60ch (when transmission rate is 19200 bps)RatingPower supply voltageTerminal (M3 screw), 12-24VDCCurrent consumption1AOperating temperature (humidity) range 0 to 40 ºC (RH 20 to 80%, no condensation)Storage temperature (humidity) range-10 to 50 ºC (RH 20 to 80%, no condensation)External dimensions144(W) × 72(H) × 139(D) mmMassApprox. 1000 gStandard accessoriesFixing foot (4), connecting bracket (4), fixing screw M4 × 8 (8)Applicable probesFor probes, refer to G-33, 34.

元のページ 

page 470

※このページを正しく表示するにはFlashPlayer10.2以上が必要です