MEASURING INSTRUMENTS CATALOG No.E2016
467/682

G-36GMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.SERIES 519 Mu-checker (Analog/Digital electronic micrometer)•Single touch zero-set function is standard.•Switchable measurement ranges make the Mu-checker suitable for a range of applications.•Two types of analog instrument and one display are available.Standard type519-551Differential type519-553Analog Mu-checkerOptional Accessories• Vertical stand (271214) Attached to the bottom surface of the Mu-checker, it can be vertically mounted on the base.• SPC Cable for connecting digital Mu-checker (936937)Used for connecting to the digimatic mini-processor.• Output cable A (934795)Used for connecting to external devices, such as data recorders, etc.• Analog, limit out (7P) connector (529035)Used for output to external data recorders, sequencers, etc.1m7PBanana chipsRefer to Catalog No. E13003 (Mu-checker) for more details.SPECIFICATIONSMetricOrder No.519-551*519-553*TypeStandard type (one probe required)Differential type (one/two probes required)Display range±5μm/±15μm/±50μm/±150μm/±500μm/±1500μmResolution0.1μm/0.5μm/1μm/5μm/10μm/50μmDifferential mode±A±A, ±B, ±A±BDisplay accuracy (linearity)±1% / ±full scaleAnalog output±1V ±full scaleAnalog output accuracy±0.1% Within ±full scale (excluding probe)Zero-setting adjustment rangeManual Instant zero setting: 1/3 of full scale for each rangeExternal dimensions 134(W) × 183(D) × 208(H) mmMass2.4kgPower inputAC adapter 100, 120, 220, 240VAC 50/60HzProbeVarious probes (refer to page G-33 and G-34)* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE.InchOrder No.519-552*519-554*TypeStandard type (one probe required)Differential type (one/two probes required)Display range±5μm/±15μm/±50μm/±150μm/±500μm/±1500μm±.00015"/±.0005"/±.0015"/±.005"/±.015"/±.05"Resolution0.1μm/0.5μm/1μm/5μm/10μm/50μm.000005"/.00001"/.00005"/.0001"/.0005"/.001"Differential mode±A±A, ±B, ±A±BDisplay accuracy (linearity)±1% / ±full scaleAnalog output±1V ±full scaleAnalog output accuracy±0.1% Within ±full scale (excluding probe)Zero-setting adjustment rangeManual Instant zero setting: 1/3 of full scale for each rangeExternal dimensions 134(W) × 183(D) × 208(H) mmMass2.4kgPower inputAC adapter 100, 120, 220, 240VAC 50/60HzProbeVarious probes (refer to page G-33 and G-34)* To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE.

元のページ 

page 467

※このページを正しく表示するにはFlashPlayer10.2以上が必要です