MEASURING INSTRUMENTS CATALOG No.E2016
456/682

G-25GLinear GageIdeal for integration into harsh environments such as automation applicationsMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.542 series 6channel input counterEV-16P/Z/D•Up to six gages can be connected to one unit, extendable up to 10 units (60 gages at maximum) using the RS Link function* to facilitate the conguration of a multi-point measurement system.* Refer to "Quick Guide to Precision Measuring Instruments" on page G-32 for details of the RS link.•A range of output modes to choose from: I/O output for tolerance judgment and segment output, BCD data output and RS-232C output are available.•Other than normal measurement, peak measurement or differential measurement between gages are available.Function• External Control (Zero-set, Preset etc.)• Direction switch• Error display• Tolerance judgment output• Diverse data output (RS-232C, BCD, Segment)• Peak measurement Maximum value, minimum value, runout, and differential measurement between two gagesAddition, averaging, maximum value, minimum value, and maximum widthOptional Accessories• ID-EV External display unit: 02ADD400• SPC cable (0.5m): 02ADD950• SPC cable (1m): 936937• SPC cable (2m): 965014• AC adapter: 02ADN460• AC cable (Japan): 02ZAA000*• AC cable (USA): 02ZAA010*• AC cable (EU): 02ZAA020*• AC cable (Britain): 02ZAA030*• AC cable (China): 02ZAA040*• AC cable (Korea): 02ZAA050*• Terminal connecting cable: 02ADD930** Required when using AC adapter.542-063542-067542-064SPECIFICATIONSOrder No.542-063542-067542-064Number of input channels6Maximum input frequency1.25MHz (2-phase square wave), response speed depends on gage specification. Max. counting speed: 5MHz 1.25MHz (2-phase square wave), response speed depends on gage specification. Max. counting speed: 5MHzResponse speed depends on gage specification.Quantizing error±1 countResolution( ) indicates maximum display range10µm (±999999.99mm) / .0005" (±9999.9995")5µm (±999999.995mm) / .00005" (±999.99995")0.5µm (±9999.9995mm) / .000005" (±.99.999995")*1[Parameter set]10µm (±999999.99mm) / .0005" (±9999.9995")5µm (±999999.995mm) / .00005" (±999.99995")1µm (±99999.999mm) / .00005" (±999.99995")0.5µm (±9999.9995mm) / .000005" (±.99.999995")[Parameter set]Depends on gage specification. LED display8 digits for parameter display (displays settings), 1 for error displayError messageOverspeed, gage error etc.External displayDedicated external display unit D-EV (optional) can be connected.Number of input switches4Function of input switchesMeasurement mode switching, parameter settingInput/output Tolerance judgment output1 to 6 channels (L1, L2, L3), open-collectorBCD outputParallel BCD output (positive/negative-true logic), open-collectorSegment outputFunction to set on only the terminals corresponding to the counting values, open-collectorControl outputNormal operation signal (NOM), open-collectorControl inputOutput channel designation (segment, in the BCD mode), presetting, peak value clear, range changeover (at segment output), holding counting valueopen-collector or no-voltage contact signal (with/without contact point)InterfaceRS-232CMeasurement data output and control inputEIA RS-232C-compatibleUse cross cables for home position, DTE (terminal definition).RS linkMax. connecting unit: 10 (6 when using EF counter)Connecting cable length: Max. 10m (sum of link cable length)Data transfer time: 1sec./60ch (when transmission rate is 19200bps)RatingPower supply voltage 12 - 24V DC, terminal block (M3 screw)Power consumption8.4W or less (700mA max.)Ensure at least 1A is available per unit.Operating temperature (humidity) range0 to 40°C (RH 20 to 80%, no condensation)Storage temperature (humidity) range–10 to 50°C (RH 20 to 80%, no condensation)External dimensions144 (W) × 72 (H) ×139 (D) mmMassApprox. 910gApprox. 910gApprox. 830gStandard AccessoriesFixing foot (4), connecting bracket (4), fixing screw M4×12 (8)Applicable inputDifferential square-waveDigimatic code (SPC)Applicable gage headLGE, LGF, LGK, LGB, LGM, LGModels with reference point mark, sine wave output type are excluded.LGF with reference point markLGD, LGS*1: Available when using D-EV. Refer to the Linear Gage (Catalog No.E13007) for more details.

元のページ 

page 456

※このページを正しく表示するにはFlashPlayer10.2以上が必要です