MEASURING INSTRUMENTS CATALOG No.E2016
37/682

A-10AMitutoyo operates a policy of continuous improvement that aims to provide the customer with the benet of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specication without notice.Common optional softwareIT-016U/USB-ITN and U-WAVEUpgraded USB-ITPAK now supports U-WAVE, a wireless communication system. Both wired connection (IT-016U/USB-ITN) and wireless system (U-WAVE) are supported. The combined use with USB-ITPAK V2.0 will improve the operational efficiency of repetition inspection work. Best suited for keeping track of inspection data of mass-produced products.This USB adapter for connecting a PC is required when using the Foot Switch (No. 937179T) in USB-ITN. A dedicated VCP driver* for this adapter is included in USB-ITPAK.• With USB-ITPAK, application of the foot switch can be set.• Data control: “Data request”,“Data cancel”, “Data skip”• Character string input (e.g. GO/NG, etc.)*USB-FSW is used for installation of the VCP driver.Main features of USB-ITPAK V2.0Main specication Operating environmentLanguage support• Operation language (15 languages)Japanese, English, German, French, Spanish, Italian, Czech, Swedish, Turkish, Polish, Hungarian, Russian, Korean, Chinese (traditional/simplied), and Simplied Chinese• Operation manual (PDF le)Japanese, English, GermanUSB-ITPAK V2.0 USB dongleA USB dongle must be connected to the PC running the software.Compatible OS *1Windows 2000 SP4Windows XP SP2 or laterWindows VistaWindows7Windows8Windows8.1Supported Excel versions *2Excel 2000Excel 2002Excel 2003Excel 2007Excel 2010Excel 2013Hard diskFree space of more than 10MBCD-ROM driveFor program installationUSB port *32 ports or moreMonitor resolution800×600, 256 colors or more*1: 32-bit, 64-bit OS supported*2: Operation with Excel for MAC OS is not guaranteed.*3: A commercially available hub can be used. (USB certified product is recommended)USB-FSWMeasurement data collection software USB-ITPAK V2.0 (IT-007R are not supported)New functions of USB-ITPAK V2.0• Supports the U-WAVE wireless communication system • Timer input function• Measurement date/time display• Others: Compatible with Windows 8, 64-bit OS, and Russian included in the operating language selectionUSB Foot Switch Adapter USB-FSWUSB-ITPAK V2.0 creates a procedure to input data from gages equipped with Digimatic output to Excel sheets via USB-ITN or U-WAVE. This optional software facilitates the daily inspection work for mass-produced products.• Automatically calls Excel sheet.• Cursor moves can be specified.• Input range can be specified per Digimatic gage, which reduces improper input.• The last data input can be canceled by a single operation (foot switch, function key etc.)• Data input or cancellation can be performed at once in multiple-point simultaneous measurement.• Setting of Microsoft Excel input: Designation of where to input (workbook, worksheet, cell range), cursor move (right, down), and others.• Selection of measuring method (3 modes available) (1) Sequential measurement (2) Simultaneous measurement (3) Individual measurement (refer to page A-12 for details).• Control item and instruction at data input (Note 1: Not available during individual measurement, Note 2: Not available during simultaneous measurement in the event drive mode)• Number of connectable gages (Note 3: The actual number can be less depending on the system conguration.)• Data loading time: when using USB-ITN, 0.2s to 0.3s per gage unitU-WAVE event drive mode: 0.5s data refresh interval• Timer input function (only in simultaneous measurement)Input interval (time): 0.1s (Note 4) to 24 hours at maximum(Note 4: If a shorter time is set, a priority is given to the longer time compared with the actual communication time.)• Measurement date/time display function (available in sequential and simultaneous measurements)The display format is subject to the setting of the Excel sheet.Available devicesMaximum number of connection (total of (1), (2), and (3))Others(1) IT-016U/USB-ITN For Windows 2000/XP Up to 100 units (Note3) For Windows Vista/7/8 Up to 20 units (Note3) For U-WAVE-R, plus 100 per unit ( in terms of available gages. ) • Maximum registration (total of (1), (2), and (3)) 400 units(2) USB-FSW(3) U-WAVE-R Up to 100 gages can be per one unit of U-WAVE. ( U-WAVE-T ID: 00 to 99 ) • Control/identification of connecting gage VCP (Virtual COM port) Switch from HID to VCP for (1) and (2). The VCP driver software is supplied with USB-ITPAK.Control itemMouse operationFunction keyFoot switch + USB-FSWData switch when using U-WAVE Data switch other than U-WAVEData output request ✓ (Note 1) ✓ (Note 1)✓ ✓ (Note 2)✓Data cancel ✓ (Note 1) ✓ (Note 1)✓✓ Press and hold (Note 2)–Data skip ✓ (Note 1) ✓ (Note 1)✓––Character input (example: OK or NG etc.)–– ✓Pre-registered character strings––Foot switch (No.937179T)Order No. Order No. PriceFoot Switch Adapter USB-FSWModel No.USB-ITPAK V2.0Order No.06AEN846Upgrade pricing from V1.0 is not available. Please purchase V2.0.Model No.USB-FSWOrder No.06ADV384Overall length: 160mm

元のページ 

page 37

※このページを正しく表示するにはFlashPlayer10.2以上が必要です